25 Pair Cable Cat3, 1000ft AWG24 CMR, PVC Gray, Belden 1232A. Telephony and Cctv. SHIPMENT FREE CANADA
25 Pair Cable Cat3, 1000ft AWG24 CMR, PVC Gray, Belden 1232A. Telephony and Cctv. SHIPMENT FREE CANADA
Suitable Applications |
802.3 10BaseT, 100BaseT4 |
---|
AWG | Stranding | Material | No. of Pairs |
---|---|---|---|
24 | Solid | BC - Bare Copper | 25 |
Conductor Count |
50 |
---|---|
Total Number of Pairs |
25 |
Material |
---|
PO - Polyolefin |
Bonded-Pair |
N/A |
---|
Number | Color |
---|---|
1 | White/Blue Stripe & Blue/White Stripe |
2 | White/Orange Stripe & Orange/White Stripe |
3 | White/Green Stripe & Green/White Stripe |
4 | White/Brown Stripe & Brown/White Stripe |
5 | White/Gray Stripe & Gray/White Stripe |
6 | Red/Blue Stripe & Blue/Red Stripe |
7 | Red/Orange Stripe & Orange/Red Stripe |
8 | Red/Green Stripe & Green/Red Stripe |
9 | Red/Brown Stripe & Brown/Red Stripe |
10 | Red/Gray Stripe & Gray/Red Stripe |
11 | Black/Blue Stripe & Blue/Black Stripe |
12 | Black/Orange Stripe & Orange/Black Stripe |
13 | Black/Green Stripe & Green/Black Stripe |
14 | Black/Brown Stripe & Brown/Black Stripe |
15 | Black/Gray Stripe & Gray/Black Stripe |
16 | Yellow/Blue Stripe & Blue/Yellow Stripe |
17 | Yellow/Orange Stripe & Orange/Yellow Stripe |
18 | Yellow/Green Stripe & Green/Yellow Stripe |
19 | Yellow/Brown Stripe & Brown/Yellow Stripe |
20 | Yellow/Gray Stripe & Gray/Yellow Stripe |
21 | Purple/Blue Stripe & Blue/Purple Stripe |
22 | Purple/Orange Stripe & Orange/Purple Stripe |
23 | Purple/Green Stripe & Green/Purple Stripe |
24 | Purple/Brown Stripe & Brown/Purple Stripe |
25 | Purple/Gray Stripe & Gray/Purple Stripe |
Material | Nominal Diameter | Ripcord |
---|---|---|
PVC - Polyvinyl Chloride | 0.399 in | No |
Max. Conductor DCR | Max. DCR Unbalance |
---|---|
93.8 Ohm/km | 5 % |
Max. Capacitance Unbalance | Nom.Mutual Capacitance |
---|---|
330 pF/100m | 15 pF/ft |
Frequency [MHz] | Max. Delay | Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
---|---|---|---|
16 MHz | 543 ns/100m | 1.5 ns/ft | 70% |
Frequency [MHz] | Max. Insertion Loss (Attenuation) | Min. PSNEXT [dB] | Min. SRL (Structural Return Loss) | Max./Min. Fitted Impedance |
---|---|---|---|---|
1 MHz | 2.6 dB/100m | 41.0 dB | 12.0 dB | 100 ± 15 Ohm |
4 MHz | 5.6 dB/100m | 32.0 dB | 12.0 dB | 100 ± 15 Ohm |
8 MHz | 8.5 dB/100m | 27.0 dB | 12.0 dB | 100 ± 15 Ohm |
10 MHz | 9.7 dB/100m | 26.0 dB | 12.0 dB | 100 ± 15 Ohm |
16 MHz | 13.1 dB/100m | 23.0 dB | 10.0 dB | 100 ± 15 Ohm |
UL Voltage Rating |
---|
300 V RMS |
Installation Temperature Range |
0°C To +50°C |
---|---|
UL Temp Rating |
60°C |
Storage Temperature Range |
-20°C To +60°C |
Operating Temperature Range |
-20°C To +60°C |
Bulk Cable Weight |
90 lbs/1000ft |
---|---|
Max. Pull Tension |
150 lbs |
Min. Bend Radius During Installation |
2.75 in |
Min. Bend Radius/Minor Axis |
2.25 in |
NEC/(UL) Compliance |
CMR |
---|---|
CEC/C(UL) Compliance |
CMR |
CPR Euroclass |
Eca |
Data Category |
Category 3 |
ANSI Compliance |
S-90-661-2012 Category 3, ANSI/NEMA WC-63.1 Category 3 |
TIA/EIA Compliance |
ANSI/TIA-568-C.2 Category 3 |
IEEE Compliance |
802.3 10BaseT, 100BaseT4 |
Third Party Performance Verification |
Category 3 |
Environmental Space |
Riser |
---|---|
EU Directive 2000/53/EC (ELV) |
Yes |
EU Directive 2002/96/EC (WEEE) |
Yes |
EU Directive 2003/11/EC (BFR) |
Yes |
EU Directive 2003/96/EC (BFR) |
Yes |
EU Directive 2011/65/EU (RoHS 2) |
Yes |
EU Directive 2012/19/EU (WEEE) |
Yes |
EU Directive 2015/863/EU (RoHS 2 amendment) |
Yes |
EU Directive Compliance |
Yes |
EU CE Mark |
Yes |
EU REACH SVHC Compliance (yyyy-mm-dd) |
2017-07-10 |
MII Order #39 (China RoHS) |
Yes |
Suitability - Aerial |
No |
---|---|
Suitability - Burial |
No |
Suitability - Hazardous Locations |
No |
Suitability - Indoor |
Yes |
Suitability - Non-Halogenated |
No |
Suitability - Oil Resistance |
No |
Suitability - Outdoor |
No |
Suitability - Sunlight Resistance |
No |
UL Flammability |
UL 1666 Riser |
---|---|
UL voltage rating |
300 V RMS |
Plenum (Y/N) |
No |
---|
Footnote |
C - CRATE REEL PUT-UP. |
---|---|
Notes |
Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings. Notes: Jacket sequentially marked at 2 ft. intervals. Third party verified to TIA/EIA-568-B.2, Category 3. NEXT is Power Sum tested |
Update and Revision |
Revision Number: 0.486 Revision Date: 12-12-2023 |
---|